FULLY INSURED·TEXT (516) 399-0350

XIRI Facility SolutionsESD-Safe Floor Care, Conductive Waxing & ANSI/ESD S20.20 Resistance Testing in West Hempstead

Electrostatic discharge prevention for electronics assembly, aerospace, defense, medical device labs, and data centers in Nassau, Suffolk & Queens. Calibrated megohmmeter testing (10⁵–10⁹ Ω), ACL Staticide finishes, and documented compliance.

Nightly Audits
100% Insured

Serving West Hempstead (11552)

XIRI provides esd-safe floor care (ansi/esd s20.20) services for facilities in West Hempstead, NY and the surrounding Nassau County area. West Hempstead, a hamlet within the Town of Hempstead, is a bustling community in Nassau County. With a population of nearly 20,000 residents, the area around Hempstead Tpke and Woodfield Rd is a local commercial hub.

Why One Wrong Floor Wax Visit Destroys Your ESD Protection

In electronics manufacturing, aerospace/defense assembly (along the Route 110 Melville and Hauppauge Industrial Park corridors), semiconductor labs, and hospital imaging suites, your conductive or static-dissipative VCT, epoxy, or rubber floor is your primary ground path. If a standard janitorial crew applies regular commercial floor wax or cleans with an insulating surfactant, they create a dielectric barrier over your conductive tiles — spiking surface resistance above 10⁹ ohms and exposing sensitive PCBs, avionics, and medical devices to catastrophic latent ESD failures.

Our ANSI/ESD S20.20 & STM7.1 Certified Floor Protocol

XIRI treats ESD floor maintenance as a calibrated engineering procedure. When stripping failed or insulating wax from ESD vinyl or epoxy, we use non-ammoniated, ESD-approved strippers and low-RPM pads that never abrade embedded carbon veins or copper grounding strips. We apply 2–3 thin, cross-linked coats of certified static-dissipative finish (such as ACL Staticide Ultra II or Statguard) and perform pre- and post-service 5-pound electrode megohmmeter testing per ANSI/ESD STM7.1. Your Quality & Compliance Director receives a signed resistance log (Rtt and Rtg in ohms, temperature, and relative humidity) after every visit.

Technical & Compliance Checklist

Point-to-Point (Rtt) & Point-to-Ground (Rtg) megohmmeter testing before and after service (10⁵ to 10⁹ ohms)

ANSI/ESD STM7.1-2020

Application of certified static-dissipative floor finish (ACL Staticide / Statguard) — zero insulating acrylic wax

ANSI/ESD S20.20-2021

Neutral-pH ESD cleaner maintenance that preserves conductive carbon/copper grounding grids

ESD TR20.20

ESD heel-strap & footwear system resistance verification for all floor technicians

ANSI/ESD STM97.1

Copper grounding strip continuity & adhesive residue inspection prior to recoat

IPC / Defense Standard

Related Services in West Hempstead

Project Spotlight · Elmont, NY (Nassau County)

Trusted at UBS Arena for Georgia-Pacific's IoT Soap Dispensing Hardware Deployment

When Georgia-Pacific needed field execution for connected, smart soap dispensing hardware at UBS Arena, XIRI delivered. We bring that exact same technical precision, hygiene accountability, and supply-chain reliability to private dental practices, medical suites, and commercial facilities across Long Island & Queens.

Frequently Asked Questions

Do you test and log floor conductivity in ohms after stripping and waxing?

Yes. Using a calibrated megohmmeter and dual 5-lb cylindrical electrodes per ANSI/ESD STM7.1, we measure Point-to-Point (Rtt) and Point-to-Ground (Rtg) resistance across multiple grid points before and after service to certify your floor remains within the 1.0 × 10⁵ to 1.0 × 10⁹ ohm specification.

Can you fix an ESD floor that a previous cleaner ruined with regular commercial floor wax?

Yes. This is one of our most common emergency requests. We perform a controlled chemical strip to remove the insulating acrylic wax layers down to the bare conductive vinyl or epoxy tile, test the underlying copper ground path, and restore conductivity with an ANSI/ESD S20.20-compliant dissipative polymer finish.

What ESD floor finishes and daily cleaners do you use?

We use industry-standard static-dissipative finishes (including ACL Staticide and Statguard) and zero-residue neutral ESD daily cleaners — never oil-based dust mops, silicone sprays, or standard Mop & Glo products.

Need ESD-Safe Floor Care (ANSI/ESD S20.20) in West Hempstead?

Book a free site audit in West Hempstead. We'll assess your facility and build a compliance-ready protocol.

Direct Project Desk: (516) 399-0350

Get Your ESD-Safe Floor Care (ANSI/ESD S20.20) - West Hempstead Scope

See what you should be paying. Enter your details to get a data-backed cleaning quote in under 2 minutes.

Skip the form · Text us directly
Text (516) 399-0350 for a Walkthrough

Text your facility type & town — our operations desk replies in minutes.

XIRI AI Advisor

Facility management expert

Hi! I'm XIRI's facility advisor. I can help you understand how our verified facility management works, what services we cover, and whether we're a fit for your building.

Ask anything, or pick a question below 👇

Powered by XIRI AI · Responses may not be 100% accurate